Tensor · Lattice OS
Gr

How many megawatts you can add, and what takes them away

Certified headroom for a new data center, generating project, or lunar base load, with the demand and the outage that would invalidate it.
conditional DC and nonlinear AC headroommillion-bus networksevery single-line outage

Before a lunar base adds a habitat module, an oxygen plant, or a rover depot, someone has to say how much load its surface network can carry, and what happens when a cable fails. On Earth, the same question decides where a data center connects and how large a generating project can be. The usual answer re-runs a power-flow study for every outage and every demand case, and hands back a number without its reasons. Tensor Grid hands back the number with its certificate: the megawatts you can rely on across your whole range of demand and every single-line outage, and the exact demand and outage that would take them away — checked independently, before you build.

THE TEST   A new load on a 1,000,000-bus meshed network, across a declared range of demand, with the network intact and after each of its 1,998,000 single-line outages. The same questions went to the HiGHS solver, kept warm, on the same desktop.
THE RESULT   Headroom certified for the whole range and every outage, then answered from the certificate:
Million-bus headroom atlas

Answered from the certificate

1,000,000 buses, every single-line outage, one desktop computer. Lower is better.

29,925× faster per question · 99.1% less memory measured, one desktop
Conditional DC headroom on the rectangular meshed network family of the cited preprint (§27.2), with bounded generation at every bus; each outage is redispatched independently, with no load shed and no project curtailed. Both sides kept their loaded state warm: HiGHS 1.15.1, one solver thread. One desktop computer, 7–8 October 2026. Exact readings.
The answer comes with its conditions

115 MW guaranteed. 120 MW conditional.

A new load at 1,000,000 buses. Demand rises by q at every bus, and by r more at alternating buses and the project.

120 MW is safe throughout 0 2 4 6 8 10 0 1 2 3 4 5 q, demand increase at every bus (MW) r, extra increase (MW)
Network intact
SAFE INFEASIBLE q + r = 10 MW 0 2 4 6 8 10 0 1 2 3 4 5 q, demand increase at every bus (MW) r, extra increase (MW)
Either line into the project out
A 120 MW project is proved safe throughout with the network intact. With either line into the project out, it is safe exactly while q + r stays at or under 10 MW, and proved infeasible above that line. 115 MW is safe across the whole range and every single-line outage. You learn which outage limits you, not just a number.
questionTensorcomparatorresult
DC headroom, 1,000,000 buses, every single-line outage0.0202 ms
25.3 MB
warm HiGHS
605.607 ms, 2.8 GB
115 MW certified
794-byte certificate
Ready to answer at 1,000,000 buses16.50 s
all 1,998,000 outages
warm HiGHS
15.37 s, one outage
every outage
in the time of one
AC headroom, 1,000,000 buses, every single-line outage6.52 µs
26.0 MB
warm Newton, replay
3.094 s, 211.7 MB
27.529101 MW
439-byte certificate
AC headroom on the PGLib 14‑bus network, new load at bus 144 MW certified
18 proof cells
—every original limit
intact and two outages
DC-OPF exact certificates on public PGLib cases14 of 14
through 78,484 buses
independent
checker
certified optimal
built in 108.0 s
checked in 68.7 s
DC-OPF, 250,000 buses, meshed network3.15 s
0.6 GB
Mehrotra interior point
481.89 s, 4.1 GB
153× faster
AC-OPF, 250,000 buses, peak memory10.3 GBMIPS, in Python
22.4 GB
54.0% less memory

Every outage, in the time it takes to load one

At a million buses, Tensor proved all 1,998,000 single-line outages in 16.50 s, about the time HiGHS took to prepare a single outage model (15.37 s). From then on every question is a lookup: 100,000 exact questions in about three seconds, each answered safe or proved infeasible, at every network size from 1,024 buses to a million.

A data center or a power plant, one question

A data center needs its full load, every hour; a generating project is certified on what it can actually deliver, never on nameplate it would have to curtail. On PGLib’s public 14-bus network, a conservative DC study certified 61.1 MW of new load at bus 14 across its declared demand range and network states, and, in a companion study, 90.9 MW of new generation. The same study names the limit: with line 9–14 out, the project sits behind the 76 MW line 13–14, with 14.9 MW of local demand already on it.

On the full AC equations

On the same public network, with every voltage, reactive-power, line-rating, and angle limit of the original case, 4 MW of new load at bus 14 is certified across 0 to 2% demand growth, intact and with either of two lines out. On a million-bus AC network at 2% growth, 27.529101 MW is guaranteed for every one of 1,998,000 single-line outages against a proved upper bound of 28.000000 MW, by a 439-byte certificate; each question is answered in 6.52 µs from 26.0 MB, against 3.094 s and 211.7 MB for a warm Newton solve with replay.

Optimal power flow at scale

The 14 public PGLib-OPF networks through 78,484 buses were each certified optimal and independently verified, the largest built in 108.0 s and checked in 68.7 s. On a 250,000-bus meshed network, Tensor solved DC optimal power flow in 3.15 s and 0.6 GB, against 481.89 s and 4.1 GB for a sparse Mehrotra interior-point solver on the same equations: 153× faster. On AC optimal power flow at the same size it used 54% less memory than MIPS, MATPOWER’s interior-point solver, in Python. Across 66 public PGLib-OPF cases and six meshed networks, 297 of 297 qualification jobs were accepted, including case8387_pegase, where MIPS failed.